CGZNM - P-75, THORNEL PITCH & THERMALGRAPH BASED ON (SUPDAT)
- MSDS: CGZNM
- Manufacturer: AMOCO PERFORMANCE PRODUCTS INC
- Product Name: P-75, THORNEL PITCH & THERMALGRAPH BASED ON (SUPDAT)
- National Stock Number: 9390-00N011106
Product Identification
Product ID:P-75, THORNEL PITCH & THERMALGRAPH BASED ON (SUPDAT)
MSDS Date:06/16/1997
FSC:9390
NIIN:00N011106
MSDS Number: CGZNM
Responsible Party
CHICAGO, IL 60601
US
Emergency Phone: 800-424-9300(CHEMTREC)
Info Phone: 312-856-3340
Cage: 15958
Contractor
Telephone: 800 447-8735
Cage: 15958
Ingredients
CARBON; (CARBON FIBER, PITCH BASED)
CAS: 7440-44-0
RTECS: FF5250100
Fraction By Weight: 100%
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 2 MG/M3 TDUST
ARE USED/HNDLD SHOULD BE PROPERLY PROTECTED AGAINST
RTECS: 9999999ZZ
INVOLVING CHRONIC APPLICATION OF PITCH
RTECS: 9999999ZZ
WEAK LOC TUMORIGENIC RESPONSE. BENZENE EXTRACT OF
RTECS: 9999999ZZ
GENETIC EFTS.
RTECS: 9999999ZZ
MEETS CRITERIA FOR BEING TOX, CORR,
RTECS: 9999999ZZ
SUBPART C). THIS MATL COULD ALSO BECOME HAZ WASTE IF
RTECS: 9999999ZZ
IF IT IS HAZ WASTE, REGS IN 40 CFR 262-266, 268, 270
RTECS: 9999999ZZ
FIBERS. NIOSH REC EXPOS LIM OF 3 FIBERS/CC FOR
RTECS: 9999999ZZ
RECS EXPOS GUIDELINE OF 3 FIBERS/CC UP TO 10
RTECS: 9999999ZZ
CONSERVATIVE APPROACH & INCLS ALL FIBER DIAMETERS IN
RTECS: 9999999ZZ
OUR MFG OPERATIONS HAVE BEEN LOW-TYPICALLY 0.01-0.02
RTECS: 9999999ZZ
CHOPPING OPERATIONS.
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:THIS PROD HAS BEEN EVAL & DOES NOT REQ
ANY HAZ WARNING ON LBL UNDER OSHA CRITERIA. HNDLG &/OR PROCESSING
OF THIS MATL MAY GENERATE AIRBORNE FIBERS & PARTICLES WHICH CAN
CAUSE MECH IRRIT OF EYES, SKIN, NOSE & THROAT. EYE/SKIN CONT:NO
SIGNIFICANT HLTH HAZS IDENTIFIED. PARTICLES/FIBERS MAY CAUSE SLIGHT
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:DISCOMFORT SIMILAR TO GETTING DUST IN
EYE/RUBBING SAND AGAINST SKIN. INHAL:NO SIGNIFICANT IRRIT EXPECTED
OTHER THAN POSS MECH IRRIT. INGEST:NO SIGNIFICANT HLTH HAZS
IDENTIFIED. TOX INFO:DENSE DUST GENERATED BY HNDLG &/OR PROCESSING
OF THIS MATL MAY BE IRRIT TO EYES, SKIN, NOSE & THROAT. STUDIES
(ING 3)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYES:FLUSH W/PLENTY OF WATER FOR AT LEAST 15 MINUTES. GET
MEDICAL ATTENTION IF IRRITATION PERSISTS. SKIN:WASH EXPOSED SKIN
W/SOAP & WATER. INHAL:REMOVE TO UNCONTAMINATED AREA. GET MEDICAL
ATTENTION. I NGEST:IF LARGE AMOUNT IS SWALLOWED, GETMEDICAL
ATTENTION.
Fire Fighting
Extinguishing Media:AGENTS APPROVED FOR CLASS A HAZARDS (E.G., FOAM,
STEAM) OR WATER FOG.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:FIBER, DUST & FIBROUS PARTICLES ARE
ELECTRICALLY CONDUCTIVE & CAN CAUSE SHORTING IN ELEC EQUIP. EXPLO
SHORTING OF HIGH VOLTAGE SYSTEMS IS POSS. CARBON (SUPDAT)
Accidental Release
Spill Release Procedures:CONTAIN & REMOVE BY MECHANICAL MEANS. VACUUM
OR SWEEP OUT; AVOID PRODUCING DUST.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:MINIMIZE DUST GENERATION &
ACCUMULATION. NO SPECIAL STORAGE REQUIREMENTS.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:IF VENT IS INADEQ, USE NIOSH APPRVD RESP THAT
WILL PROT AGAINST DUST/MIST. CURRENTLY NO HLTH STDS EXIST FOR
EMPLOYEE EXPOS TO CARBON FIBERS. IN 1977, NIOSH PROPOSED THAT THEIR
REC STD FOR FIBROUS GLAS S BE APPLIED TO OTHER MAN-MADE (ING 9)
Ventilation:NO SPECIAL CONTROLS NECESSARY. LOCAL EXHAUST VENTILATION
MAY BE NECESSARY FOR SOME OPERATIONS.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPRVD EYE WASH FOUNTAIN & DELUGE
SHOWER. LONG SLEEVE-GARMENTS W/TIGHT-FITTING CUFFS & USE OF
BARRIER(SUPDAT)
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
MFR'S TRADE NAME/PART NO:HIGH & ULTRA-HIGH MODULUS FIBER. OTHER PROT
EQUIP:CREAMS/TALCUM PROVIDE ADDNL PROT TO SKIN. EXPLO HAZ:FIBERS
ARE ELECTRONICALLY CONDUCTIVE & MAY CAUSE SHORT CIRCUITS WHICH RSL
T IN DMG TO/MALFUNCTIONING ELEC EQUIP. ALL FORMS OF ELEC EQUIP,
ENCLOSURES & CIRCUITS IN/NEAR AREAS WHERE FIBERS (ING 2)
Chemical Properties
Melt/Freeze Pt:M.P/F.P Text:6512F,3600C
Solubility in Water:NEGLIGIBLE; <0.1%.
Appearance and Odor:BLACK CARBON FIBER, FABRIC OR CLOTH.
Stability
Stability Indicator/Materials to Avoid:YES
NONE IDENTIFIED.
Stability Condition to Avoid:AVOID GENERATING DUST.
Hazardous Decomposition Products:NONE IDENTIFIED.
Disposal
Waste Disposal Methods:DISP MUST BE I/A/W APPLIC FED, STATE/LOC REGS.
DO NOT INCIN. BURIAL AT PERMITTED LANDFILL IS REC. RCRA:THIS UNUSED
MATL, WHEN DISCARDED/DISP OF, IS NOT SPECIFICALLY LISTED AS HAZ
WASTE IN FED REGS; HO WEVER, IT COULD BE CONSIDERED HAZ IF IT(ING
6)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.